Indoor Fiber Optic Cable Simplex GJFJH SM, OM1, OM2, OM3, OM4, OM5

Indoor Fiber Optic Cable Simplex GJFJH SM, OM1, OM2, OM3, OM4, OM5
Indoor Fiber Optic Cable Simplex GJFJH SM, OM1, OM2, OM3, OM4, OM5Indoor Fiber Optic Cable Simplex GJFJH SM, OM1, OM2, OM3, OM4, OM5Indoor Fiber Optic Cable Simplex GJFJH SM, OM1, OM2, OM3, OM4, OM5Indoor Fiber Optic Cable Simplex GJFJH SM, OM1, OM2, OM3, OM4, OM5
CategoriesIndoor distribution cable
BrandRUX
ModelGJFJH
Fiber TypeSM, OM1, OM2, OM3, OM4, OM5
Cable Diameter (mm)1.4-3.0
Cable Weight (kg)2.4-7.5
Tight Buffer Fiber Diameter(um)600/900
Tensile Strength (Long term N/100mm)100
Tensile Strength (Short term N/100mm)500
Dynamic Bending Radius (mm)60
Static Bending Radius (mm)30
Application (1)Optical Fibre patch cord and pigtail
Application (2)Indoor riser lever and plenum level cable distribution
FOB portShenzhen
Terms of PaymentL/C, Western Union, MoneyGram, T/T
Download
Update TimeDec 26,2024
Detail Information
1.1    CableStructure(Indoor Fiber Optic Cable
GJFJH

1.2     Characteristics

A.   Tight buffer fiber easystrip

B.   Tight buffer fiber has excellent flame-retardant performance

C.   Aramid yarn as strengthmember make cable have excellent tensile strength

D.   The jacket anti-corrosion, anti-water, anti-ultraviolet radiation, flame-retardant and harmless to environment etc.

 

1.3     Cable Application

A.   Optical fiber jumper or pigtail

B.   Indoor riser level and plenum level cable distribution

C.   Interconnect betweeninstruments, communication equipment.

 

1.4   CableProperties

Transporttemperature: - 20 deg C to + 60 deg C

Storage Temperature: - 20 deg C to + 60 deg C

Operating temperature: - 20 deg C to + 60 deg C

Installation temperature: - 5 deg C to + 50 deg C


2. Optical Characteristics& Technical Parameters 

2.1 Technical Parameters

Cable Code
Cable Diameter
mm
Cable Weight(Ref)
kg/km
TBF Diameter
μm
Tensile strength
Long/Short term
mm
Crush Resistance
Long/short term
N/100mm
Bending Radius
Dynamic/Static
mm
PVC jacket
LSZH jacket
GJFJV(H)-1.6
1.6±0.2
2.4
2.6
600±50
40/80
100/500
60/30
GJFJV(H)-1.9
1.9±0.2
3.5
4.5
900±50
60/100
100/500
60/30
GJFJV(H)-2.8
2.8±0.2
6.0
7.5
900±50
60/100
100/500
60/30
2.2 Optical Characteristics
Fiber Type
Attenuation
OFL
Valid mode
band width
10G Ethernet
 link length SX
Min. bending
 radius
Condition
1310/1550nm
850/1300nm
850/1300nm
850nm
850nm
Typical
Max.
Typical
Max.



Unit
dB/km
dB/km
dB/km
dB/km
MHZ.km
MHZ.km
m
mm
G652D
0.36/0.22
0.5/0.4





16
G657A1
0.36/0.22
0.5/0.4
10
G657A2
0.36/0.22
0.5/0.4
7.5
OM1
3.0/1.0
3.5/1.5
500/500
2000
300
30
OM2
3.0/1.0
3.5/1.5
200/500
4700
550
30
OM3
3.0/1.0
3.5/1.5
1500/500
2000
300
30
OM4
3.0/1.0
3.5/1.5
3500/500
4700
350
30

3. Packing and shipping

 

3.1  The cables are packed in wooden drums andthen in carton box

3.2  Standard delivery length is 1km/roll or percustomer’s requirements.

3.3  Sheath Marking

The sheath marking are hotstamped on the sheath at one meter interval with white color. The accuracy ofthe length marking shall be 0 ~ +1%.

Re-marking is yellow color, ifnecessary.

RUX  ***  xxFIBRE  Month/Year  XXXXM

l RUX: Manufacturer’s Name

l ***: Customer’s name

l xxFIBRE: Fiber count

l Month/Year: Manufacturedate

l XXXXM: The figure of meter.

Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
My status