Single Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc Connector

Single Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc Connector
Single Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc ConnectorSingle Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc ConnectorSingle Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc ConnectorSingle Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc ConnectorSingle Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc Connector
CategoriesFiber Optic Splitter
BrandRUX
ModelSc Upc
Port1x2,1x4,1x8,1x16,1x32,1x64
Operating Wavelength(nm)1260~1650
Return Loss (dB)55/50
Directivity (dB)55
Operating Temperature (°C)-40~+85
Storage Temperature (°C)-40~+85
ApplicationFTTH FTTB FTTX Network
FOB portShenzhen
Terms of PaymentL/C, Western Union, MoneyGram, T/T, Paypal
Update TimeDec 5,2024
Detail Information
Description

Single Mode 1x2 1x4 1x8 1x16 1x32 1x64 PLC Box Splitter With Sc Upc Connector

The PLC splitter is a kind of integrated waveguide optical power distribution device based on quartz substrate. It has the characteristics of small volume, wide operating wavelength range, high reliability, good uniformity of spectrophotometer and so on. For passive optical network (EPON, BPON, GPON, etc.) to connect the central office and terminal equipment and to achieve optical signal shunt. The 1xN and 2xN splitters evenly divide the optical signal into multiple outlets evenly from a single or dual inlet, or vice versa, to import multiple optical signals into a single or two root fiber.

Technical Data
ITEM
Unit
Technical Parameters
Port Configuration
\
1x2
1x4
1x8
1x16
1x32
1x64
Fiber Type
\
SMF-28e or customer specified
Operating Wavelength
nm
1260~1650
Insertion Loss
Typ
dB
3.7
6.8
10.0
13.0
16
19.5
Max
dB
4.0
7.2
10.5
13.5
16.9
21.0
Loss Uniformity
Max
dB
0.4
0.6
0.8
1.2
1.5
2.5
Return Loss
Min
dB
50
50
50
50
50
50
Polarization Dependent Loss
Max
dB
0.2
0.2
0.3
0.3
0.3
0.4
Directivity
Min
dB
55
55
55
55
55
55
Wavelength Dependent Loss
Max
dB
0.3
0.3
0.3
0.5
0.5
0.8
Temperature Stability(-40~85 °C)
Max
dB
0.5
0.5
0.5
0.8
0.8
1.0
Operating Temperature
°C
-40~85
Storage Temperature
°C
-40~85
Products Features
* Low Insertion loss and low Polarization Dependent loss
* Low PDL
* High channel counts
* Compact Design
* Good channel-to-channel uniformity
* Wide Operating Wavelength: 1260-1650nm
* Wide Operating Temperature: -40°C - 85°C
* High Reliability and Stability
Application
* FTTX Systems
* PON Networks
* CATV Links
* Optical Signal Distribution
* Local Areal Networks (LAN)
* Fiber Communication Systems
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
My status